Discharge coefficient - Wikipedia
In a nozzle or other constriction, the discharge coefficient (also known as coefficient of discharge or efflux coefficient) is the ratio of the actual discharge to the ideal discharge, i.e., the ratio of the mass flow rate at the discharge end of the nozzle to that of an ideal nozzle which expands an identical working fluid … See more
Due to complex behavior of fluids around some of the structures such as orifices, gates, and weirs etc., some assumptions are made for the theoretical analysis of the stage-discharge … See more
• Mass Flow Choking, Nancy Hall, 6 April 2018 See more
Wikipedia text under CC-BY-SA license Orifice, Nozzle, and Venturi Flow Meters: Principles, Calculations …
See more on engineeringtoolbox.comAssuming a horizontal flow (neglecting the minor elevation difference between the measuring points) the Bernoulli Equationcan be modified to: The equation can be adapted to vertical flow by adding elevation heights: p1 + 1/2 ρ v12 + γ h1 = p2 + 1/2 ρ v22+ γ h2 (1b) where γ = specific weight of fluid (kg/m3, slugs/ft3) h = eleva…Periodically AFT Arrow users pose the question of what CdA value to use for modeling choked flow through an orifice. This paper reviews the subject to provide guidance in this area.
- File Size: 164KB
- Page Count: 14
How do I determine the flow rate of compressed air through a pipe ...
If flow isn't choked, you can use mdot = CdA sqrt(2 rho dp), where CdA is not actually a Cd coefficient times some area but actually a combination of loss coefficients (frictional, bends, …
- Reviews: 5
Coefficient of Discharge Calculator
The coefficient of discharge calculator will help you determine the ratio between the theoretical and actual discharge or flow rate values for a fluid flow.
Flow Through an Orifice ( English Units ) - AFT
Flow Through an Orifice (Metric Units) This example demonstrates a sample calculation to determine the maximum flow through a system where sonic choking occurs, as well as the sonic pressure and area, and it explores the effect of …
- People also ask
Flow Through Orifices. - Civil Engineering Portal
Flow through a submerged orifice may be computed by applying Bernoulli’s equation to points 1 and 2 in figure below. Values of C for submerged orifices do not differ greatly from those for nonsubmerged orifices.
restrict fluid flow. By measuring the pressure drop across this restraint, and using basic fluid me-chanics principles, one can determine the volumetric flow rate or velocity of a fluid passing t.
Coefficient Of Discharge Calculator & Formula Online Calculator …
Oct 3, 2024 · Calculation Formula. The formula to calculate the Coefficient of Discharge (C d) is: \[ C_d = \frac{Q_a}{Q_t} \] Where: \( Q_a \) is the actual flow rate (in m³/s). \( Q_t \) is the …
Generant’s Flow Calculator are mathematically equivalent to the formulas and methods described in BS EN ISO 4126-1. First, the calculator determines if the flow is choked or unchoked:
Sonic Choking Detailed Description - AFT
Sonic choking occurs when some location in the pipeline experiences a local velocity equal to the sonic velocity of the gas. AFT xStream can account for sonic choking, and approximate moving shock waves in gas systems. Sonic choking …
Modeling Choked Flow Through an Orifice - AFT
Jun 23, 2010 · To answer the question at the beginning of this paper, ‘what CdA value to use for modeling choked flow through an orifice’, that depends on the goal. If the goal is to insure a …
Discharge Coefficient - Piping Designer
Different flow devices have different discharge coefficient values, and they can vary depending on the operating conditions. By incorporating the discharge coefficient into flow calculations, more …
Orifice CdA and Sonic Choking ( English Units ) - AFT
This example demonstrates a sample calculation to determine the maximum flow through a system where sonic choking occurs, as well as the sonic pressure and area, and it explores …
Discharge Coefficient - Valvias
The discharge coefficient is a characteristic non-dimensional factor of the valve, which is used to calculate the flow rate (Q) when the valve discharges the fluid from a tank or reservoir (Δh) to …
Is This Valve Choked? - AFT
AFT Arrow's output for junctions includes the 'Sonic Area', the CdA value at the junction that would result in choked flow, and in conjunction with the pipe flow area, can be used to make a …
Orifice equation | Engineering | Fandom
The equation can be represented as: Q = C d A 2 g h {\displaystyle Q = C_ {d}A\sqrt {2gh}} where Q = flow (cubic metres per second) C d {\displaystyle C_ {d}} = coefficient of discharge A = …
Discharge Coefficient Loss Model - AFT
When solving the system, AFT xStream creates a subsonic CdA for the orifice using the Cd specified for the subsonic loss model, and the specified orifice area. xStream then solves the …
Online Flow Equations: Flow rate calculation - Valvias
K = Kv, when K is referenced in [m³/h] [bar] units. Flow equations to calculate Flow rate.
Equations for Basic Profile Calculations - hec.usace.army.mil
Equations for Basic Profile Calculations. Water surface profiles are computed from one cross section to the next by solving the Energy equation with an iterative procedure called the …
Implicit Finite Difference Scheme
The most successful and accepted procedure for solving the one-dimensional unsteady flow equations is the four-point implicit scheme, also known as the box scheme (see figure below). …
Forced Air Flow Convection Cooling Fan Air Flow Required …
The Forced Air Flow Convection Cooling Fan Air Flow Required Calculator is a tool used to calculate the required air flow rate and fan performance. It takes into account the power …
Flow Through an Orifice ( Metric Units ) - AFT
Flow Through an Orifice (English Units) This example demonstrates a sample calculation to determine the maximum flow through a system where sonic choking occurs, as well as the …