OVERLAP PROVIDING CONTINUOUS FLASHING. JM PMMA FIELD MEMBRANE USE THIS DETAIL IN CONJUNCTION WITH DETAIL L-DV-03S WHICH IS PART OF THIS …
PLEASE SEE SINGLE PLY FLASHING SPECIFICATIONS FOR A FULL DESCRIPTION OF INSTALLATION INSTRUCTIONS AND REQUIREMENTS WHICH ARE CONSIDERED A …
Refer to StoGuard Product Use Chart (Table 1.1) for StoGuard detail components; joint treatment, rough opening protection, backing for masonry anchors, or transitions to dissimilar materials, …
Roofing Detail: Typical Thru-Wall Scupper - Building …
Nov 8, 2011 · However, in roof systems with parapet walls that exceed 3 feet in height another form of water removal can be accomplished with thru-wall …
- Estimated Reading Time: 50 secs
Roofing Detail: Through-Wall Scupper Flashing
May 10, 2023 · Seal exterior of scupper at wall penetration. See Appendix A for gauge or thickness guide for sheet metal flashing. Continuous cleats are recommended when flashing face dimension exceeds 3 inches and in areas …
thru-wall scupper detail title 01/25lam2c-h-ds.14 1-888-509-3350 usa.sika.com. sikalastic 835i, base coat. refer to parapet and wall details for acceptable termination. sikalastic flashing strip.
- People also ask
CCW-500R Detail 500-18A > Carlisle Coatings and Waterproofing
May 13, 2015 · Overflow Metal Scupper, CCW-500R, CCW-500 Reinforcing Fabric, CCW-711-90, CCW Uncured Neoprene, CCW-550 Primer, Sure-Seal Lap Sealant, Sure-Seal Water Cut-off …
OVERLAP PROVIDING CONTINUOUS FLASHING. BITUMINOUS FIELD MEMBRANE USE THIS DETAIL IN CONJUNCTION WITH DETAIL LB-DV-02S WHICH IS PART OF THIS …
Refer to SMACNA recommendations and details regarding metal thickness and cleat requirements. Continuous cleats are recommended at all edges and coping flashings, cleats to …
STEP #1 - APPLY CONTINUOUS BEAD OF ELEVATE WATER BLOCK, CENTERED UNDER FASTENERS. SECURE SCUPPER METAL WITH APPROPRIATE FASTENERS. STEP #2 - …
Carlisle SynTec Systems CAD Details Search using keywords: …
Downloads for Carlisle SynTec Systems, Ca files (ref: Q:scupper overflow, 0) with architectural information on building materials, manufacturers, specifications, BIM families and CAD drawings.
Roofing Detail: Overflow Scupper Flashing | Building Enclosure
Jul 5, 2023 · Flashing or stripping ply should extend into scupper throat, and be fully welded. Seal exterior of scupper at wall penetration. See Appendix A for gauge or thickness guide for sheet …
SBS Through-wall Scupper Drain - RCABC Roofing Practices …
Interface between outside wall and scupper to be caulked with appropriate sealant. Installed by trade responsible for outside wall finish if roofing and metal flashing has been completed prior …
Through Wall Scupper Descriptions - Gutter Replacement
Mar 6, 2012 · Through wall scupper can be installed to hold water into rain gutters or directly into downspouts via conductor mind. Whenever a conductor head is used, it should be a minimum …
specifications, details and shop drawings, and for determining their suitability for a particular project or application. while sika provides general instructions for the installation of its
Roof Scuppers: What They Are, Drainage, Sizing, Codes & More
Feb 5, 2025 · Detailed, expert information on roof scuppers: code requirements, overflow scuppers, scupper sizing, location, materials, common issues, and more.
How Overflow Scuppers Save Flat Roofs from Collapse
Aug 26, 2024 · How Overflow Scupper Drains Prevent Roof Collapse. The main goal of overflow scuppers is to drain water to prevent a roof’s structural failure. Their discharge also alerts that …
What is a scupper drain? - GreenyPlace.com
Apr 1, 2025 · What is the minimum scupper size? In addition, overflow scuppers must be sized with a minimum opening height of 4 inches (102 mm) and have an opening area at least three …
Overflow Drains and Scuppers - Roof Drainage - EVstudio
Oct 28, 2009 · Where you can drain over the wall, the overflow drain must be at least the same size as the regular drain and located no more than 2″ above the low point of the roof. Where …