  1. Table 601 sprinkler substitution clarification - The Building Code …

    Oct 27, 2009 · Area can be increased to 42,000 sf if the sprinkler system is NFPA 13 system 506.3 Automatic sprinkler system increase. Where a building is equipped throughout with an …

  2. S-2 Occupancy-Sprinklers Required? - The Building Code Forum

    Jun 14, 2013 · 903.2.9 Group S-1. An automatic sprinkler system shall be provided throughout all buildings containing a Group S-1 occupancy where one of the following conditions exists: 1. A …

  3. Pavilion Occupancy....sprinklers? | The Building Code Forum

    Apr 9, 2019 · An automatic sprinkler system shall be provided for fire areas containing Group A-2 occupancies and intervening floors of the building where one of the following conditions exists: …

  4. R-2 Sprinkler System - The Building Code Forum

    Jun 8, 2017 · If the building does not have sufficient municipal water supply for design of a fire sprinkler system available to the floor without installation of a new fire pump, work areas shall …

  5. 903.2.1.2 Group A-2 sprinkler required? - The Building Code Forum

    Oct 27, 2009 · An automatic sprinkler system shall be provided for Group A-2 occupancies where one of the following conditions exists: 1. The fire area exceeds 5,000 square feet (464.5 m2); …

  6. Alteration Level 3, B Occupancy, Sprinklers Required?

    Apr 26, 2017 · No sprinkler required for Group B occupancy per IBC Section 903.2. You’re well under the allowable area for Type IIB construction, so you don’t need a sprinkler system for an …

  7. B & R3 separation & sprinkler - The Building Code Forum

    Sep 1, 2018 · If the building does not have sufficient municipal water supply for design of a fire sprinkler system available to the floor without installation of a new fire pump, work areas shall …

  8. Existing R-3 - Sprinklers or no? - The Building Code Forum

    Jun 12, 2019 · Level 2 Alterations only require the addition of a sprinkler system per Section 804.2.2 when the occupant load is greater than 30, a sprinkler system is required by the IBC …

  9. walk-in freezer, sprinklers required | The Building Code Forum

    May 22, 2019 · 4. Be protected by an automatic sprinkler system in accordance with Section 903.3.1.1. Where the cooler or freezer is within a building, both the cooler or freezer and that …

  10. NFPA 72 Water flow fire alarm signal | The Building Code Forum

    Oct 19, 2009 · 17.13.1* The provisions of Section 17.13 shall apply to devices that initiate an alarm indicating a flow of water in a sprinkler system. 17.13.2* Activation of the initiating device shall …